Installation, Operation &
Maintenance Instructions
1000°C - 1200°C Tube furnaces
types MTF, CTF
This manual is for the guidance of operators of the above Carbolite products
and should be read before the furnace is connected to the electricity supply.
Manuals are supplied separately for the furnace controller
(and overtemperature controller when fitted).
Please read the controller manuals before operating the furnace.
CONTENTS
Section page
1.0 Introduction 2
2.0 Installation 3
3.0 Operation 5
4.0 Maintenance 7
5.0 Repairs & Replacements 8
6.0 Fault Analysis 11
7.0 Circuit Diagrams 12
8.0 Fuses & Power Settings 15
9.0 Specifications 16
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Maintenance Instructions

MF03 – 3.13 Installation, Operation & Maintenance Instructions 1000°C - 1200°C Tube furnaces types MTF, CTF This manual is for the guid

Strona 2 - NTRODUCTION

MTF, CTF 10 MF03 3.13 Check the cylindrical case and clean out as appropriate. Remove any insulation sleeving from the tails of the old elemen

Strona 3 - 2.0 INSTALLATION

MTF, CTF MF03 3.13 11 6.0 FAULT ANALYSIS A. Furnace Does Not Heat Up 1. The HEAT light is ON  The heating element has failed  Check also

Strona 4

MTF, CTF 12 MF03 3.13 7.0 CIRCUIT DIAGRAMS Safety Switches type A: a 2-pole Heater Switch is fitted directly in the element circuit in models u

Strona 5 - 3.0 OPERATION

MTF, CTF MF03 3.13 13 7.4 3-phase without neutral (delta) 7.5 3-phase without neutral (star – e.g. 380 to 415V) 7.6 Higher Vo

Strona 6

MTF, CTF 14 MF03 3.13

Strona 7 - 4.0 MAINTENANCE

MTF, CTF MF03 3.13 15 8.0 FUSES & POWER SETTINGS 8.1 Fuses F1-F3: Refer to the circuit diagrams. F1 Internal supply fuses Fitted if s

Strona 8 - EPAIRS & REPLACEMENTS

Carbolite, Parsons Lane, Hope, Hope Valley, S33 6RB, England. Telephone: +44 (0)1433 620011 Fax: +44 (0)1433 621198 E-mail: [email protected] The p

Strona 9

MTF, CTF 2 MF03 3.13 1.0 INTRODUCTION 1.1 Switches and Lights 1.2 Warning Symbols Instrument switch: when the instrument sw

Strona 10

MTF, CTF MF03 3.13 3 2.0 INSTALLATION 2.1 Unpacking & Handling When unpacking or moving the furnace always lift it by its base or by both

Strona 11 - 6.0 FAULT ANALYSIS

MTF, CTF 4 MF03 3.13 2.4 Electrical Connections Connection by a qualified electrician is recommended. All furnaces covered by this manual may

Strona 12 - 7.0 CIRCUIT DIAGRAMS

MTF, CTF MF03 3.13 5 3.0 OPERATION The instructions for operating the temperature controller are given in a separate manual. If the furnac

Strona 13

MTF, CTF 6 MF03 3.13 3.4 Tube Life A ceramic work tube may be cracked if workpieces are inserted too quickly or at temperatures below 900°C (wh

Strona 14

MTF, CTF MF03 3.13 7 4.0 MAINTENANCE 4.1 General Maintenance No routine maintenance is required. The outer surfaces may be cleaned with a damp

Strona 15 - USES & POWER SETTINGS

MTF, CTF 8 MF03 3.13 5.0 REPAIRS & REPLACEMENTS 5.1 Safety Warning – Disconnection from Supply Always ensure that the furnace is disconnec

Strona 16 - 9.0 SPECIFICATIONS

MTF, CTF MF03 3.13 9 5.5 Thermocouple Replacement The coverings and guards which must be removed to gain access to the thermocouple depend on t